Choose your Region

Are you sure you want to proceed?

You will be leaving the Cook Medical website that you were viewing and going to a Cook Medical website for another region or country. Not all products are approved in all regulatory jurisdictions. The product information on these websites is intended only for licensed physicians and healthcare professionals.

iCast® Covered Stent System


The iCast covered stent system is indicated for improving luminal diameter in patients with symptomatic atherosclerotic disease of the native common and/or external iliac arteries up to 110 mm in length, with a reference vessel diameter of 5 mm to 10 mm.

This product line is serviced by the following clinical division(s):

The products on this website are available for sale in the United States. Reference Part Numbers are not the same in all countries/regions. For products available in other countries, please choose one of our other websites from the region selector at the top of the site or contact your local Cook Medical representative.

Specifications

Order Number Reference Part Number Instructions
for Use (IFU)
MR
Status
Stent
Diameter/
Length
mm
Catheter
Length
cm
Post Nominal
Pressure 8 atm
OD/Length
mm
More Info
G60480 48516
MR Conditional 5x16 80 4.9/15.9 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.2/15.6
Introducer Compatibility Fr
6
G60481 48522
MR Conditional 5x22 80 4.9/21.3 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.2/21.0
Introducer Compatibility Fr
6
G60482 48538
MR Conditional 5x38 80 5.1/37.2 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.3/37.7
Introducer Compatibility Fr
7
G60483 48559
MR Conditional 5x59 80 5.0/58.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.3/60.0
Introducer Compatibility Fr
7
G60484 48616
MR Conditional 6x16 80 5.7/15.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.2/15.1
Introducer Compatibility Fr
6
G60485 48622
MR Conditional 6x22 80 5.8/20.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.2/20.2
Introducer Compatibility Fr
6
G60486 48638
MR Conditional 6x38 80 6.0/36.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.3/37.0
Introducer Compatibility Fr
7
G60487 48659
MR Conditional 6x59 80 6.0/57.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.3/58.7
Introducer Compatibility Fr
7
G60488 48716
MR Conditional 7x16 80 6.9/15.0 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/14.2
Introducer Compatibility Fr
7
G60489 48722
MR Conditional 7x22 80 6.9/20.1 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/19.4
Introducer Compatibility Fr
7
G60490 48738
MR Conditional 7x38 80 6.9/35.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/35.7
Introducer Compatibility Fr
7
G60491 48759
MR Conditional 7x59 80 7.0/57.1 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/57.5
Introducer Compatibility Fr
7
G60492 48838
MR Conditional 8x38 80 8.1/34.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
8.5/34.7
Introducer Compatibility Fr
7
G60493 48859
MR Conditional 8x59 80 8.0/56.0 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
8.4/56.5
Introducer Compatibility Fr
7
G60494 48938
MR Conditional 9x38 80 8.9/33.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
9.3/32.7
Introducer Compatibility Fr
7
G60495 48959
MR Conditional 9x59 80 8.9/54.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
9.3/54.0
Introducer Compatibility Fr
7
G60496 48038
MR Conditional 10x38 80 10.0/30.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
10.4/30.9
Introducer Compatibility Fr
7*
G60497 42516
MR Conditional 5x16 120 4.9/15.9 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.2/15.6
Introducer Compatibility Fr
6
G60498 42522
MR Conditional 5x22 120 4.9/21.3 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.2/21.0
Introducer Compatibility Fr
6
G60499 42538
MR Conditional 5x38 120 5.1/37.2 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.3/37.7
Introducer Compatibility Fr
7
G60500 42559
MR Conditional 5x59 120 5.0/58.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
5.3/60.0
Introducer Compatibility Fr
7
G60501 42616
MR Conditional 6x16 120 5.7/15.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.2/15.1
Introducer Compatibility Fr
6
G60502 42622
MR Conditional 6x22 120 5.8/20.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.2/20.2
Introducer Compatibility Fr
6
G60503 42638
MR Conditional 6x38 120 6.0/36.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.3/37.0
Introducer Compatibility Fr
7
G60504 42659
MR Conditional 6x59 120 6.0/57.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
6.3/58.7
Introducer Compatibility Fr
7
G60505 42716
MR Conditional 7x16 120 6.9/15.0 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/14.2
Introducer Compatibility Fr
7
G60506 42722
MR Conditional 7x22 120 6.9/20.1 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/19.4
Introducer Compatibility Fr
7
G60507 42738
MR Conditional 7x38 120 6.9/35.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/35.7
Introducer Compatibility Fr
7
G60508 42759
MR Conditional 7x59 120 7.0/57.1 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
7.3/57.5
Introducer Compatibility Fr
7
G60509 42838
MR Conditional 8x38 120 8.1/34.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
8.5/34.7
Introducer Compatibility Fr
7
G60510 42859
MR Conditional 8x59 120 8.0/56.0 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
8.4/56.5
Introducer Compatibility Fr
7
G60511 42938
MR Conditional 9x38 120 8.9/33.7 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
9.3/32.7
Introducer Compatibility Fr
7
G60512 42959
MR Conditional 9x59 120 8.9/54.6 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
9.3/54.0
Introducer Compatibility Fr
7
G60513 42038
MR Conditional 10x38 120 10.0/30.8 Expand »
Additional Specs
Description
-
Post Rated Burst Pressure 12 atm OD/Length mm
10.4/30.9
Introducer Compatibility Fr
7*

* If using a 10 mm device with a Cook introducer sheath, it is recommended to use an 8 Fr sheath to minimize potential for resistance. 

The iCast covered stent system is manufactured by Atrium Medical Corporation, Merrimack, NH.

The iCast covered stent system is manufactured by Atrium Medical Corporation / 40 Continental Blvd., Merrimack, NH 03054 USA / Tel. 1 (603) 880-1433 · Protected by the following international and/or U.S. patent(s): http://patents.getinge.com. CAUTION: Federal Law (U.S.A.) restricts this device to sale by or on the order of a physician. · Getinge is a trademark or registered trademark of Getinge AB, its subsidiaries or affiliates in the United States or other countries. ICAST is a registered trademark of Atrium Medical Corporation. · Copyright 2023 Atrium Medical Corporation. · All rights reserved. · Refer to Instructions for use for current indications, warnings, contraindications, and precautions.

PI-WF247510-EN

Videos

iCast animation
6354214282112
true
brightcove

Documents

Brochure

Clinical Resource

iCast clinical data flyer

PI-WF193203-EN-F_M3_1718977195899.pdf »
English

Image Library